Power cords for North America

Cord types

Caution
The act of selling power cords certified by a North American standard (UL or c-UL) in Japan violates the Electrical Appliances and Materials Safety Act. The power cords presented below have achieved both the UL/c-UL and PSE certification and can be used in both North America and Japan

Cord types common for Japan and North America

Structure table for cords common for Japan and North America

The UL and c-UL flexible cords have been certified by UL62 and CSA C22.2 No. 49 and passed the vertical flame test (VW-1) in both UL and c-UL.

Type Conductor PVC insulator PVC sheath Conductor resistance20℃(Ω/km or less) Reference allowable current(A) Maximum rated voltage(VAC) Withstanding voltage(VAC/minute)
Type Shape Number of cores Cross- sectional area(mm²) Configuration(conductors/mm) Thickness(mm) Outside diameter(mm) Thickness(mm) Outside diameter(mm)
HVCTF/ SVT Round 3 0.75
(18AWG)
41/0.16 0.6 2.38 1.08 7.38 PSE:25.1
U/C:22.4
8 300 2,000
HVCTF/ SJT Round 3 1.25
(16AWG)
54/0.18 0.8 3.1 1.07 8.9 PSE:14.1
U/C:15.1
13
2.0
(14AWG)
41/0.26 0.86 3.63 0.98 9.85 PSE:9.8
U/C:8.88
18
Rated temperature: 60℃

back to index